Jumper Cable Selector Chart
12 Volt Jumper Cable Chart
(Approximate Jumper Cable Size Selector Chart to Achieve 1volt of Voltage Drop Max
| Note: 1volt VD @ 12v = 8.3% voltage drop |
| @ 13v = 7.7% voltage drop |
| @ 14v = 7.1% voltage drop |
| @ 15v = 6.7% voltage drop |
| |
Length of Jumper Wire |
| | | 15ft | 20ft | 25ft | 30ft | 40ft |
Load on Run | 150w | 14AWG | 12AWG | 10AWG | 10AWG | 8AWG |
| 300w | 10AWG | 8AWG | 8AWG | 6AWG | 6AWG |
24 Volt Jumper Cable Chart
(Approximate Jumper Cable Size Selector Chart to Achieve 1volt of Voltage Drop Max)
| Note: 1volt VD @ 24v = 4.2% voltage drop |
| @ 26v = 3.8% voltage drop |
| @ 28v = 3.5% voltage drop |
| @ 30v = 3.3% voltage drop |
| |
Length of Jumper Wire |
| | | 15ft | 20ft | 25ft | 30ft | 40ft |
Load on Run | 250w | 14AWG | 12AWG | 12AWG | 10AWG | 10AWG |
| 500w | 10AWG | 10AWG | 8AWG | 8AWG | 6AWG |
24 Volt Jumper Cable Chart
(Approximate Jumper Cable Size Selector Chart to Achieve 2volts of Voltage Drop Max)
| Note: 1volt VD @ 24v = 8.4% voltage drop |
| @ 26v = 7.6% voltage drop |
| @ 28v = 7.0% voltage drop |
| @ 30v = 6.6% voltage drop |
| |
Length of Jumper Wire |
| | | 15ft | 20ft | 25ft | 30ft | 40ft |
Load on Run | 250w | 14AWG | 14AWG | 14AWG | 14AWG | 12AWG |
| 500w | 12AWG | 12AWG | 12AWG | 10AWG | 10AWG |
|